ECTDS10 Non-Isolated Solution Conductivity Transmitter with RS485 Modbus, Analog Voltage, Analog Current Interface
View:7512 Category:Conductivity & TDS Category:Measurements Category:Products
ECTDS10 measures Conductivity, Salinity, TDS with temperature compensation. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage?system, irrigation, smart agriculture etc.
Resources | |
User Manual | UM-ECTDS10 Solution Conductivity Transmitter |
Software | SensorOneSet-EN |
ECTDS10 measures Conductivity, Salinity, TDS with temperature compensation. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage?system, irrigation, smart agriculture etc.
?
■ Conductivity, Salinity and TDS measurement with temperature compensation
■ With ABS or Stainless steel electrode
■ Output Interface with RS485, Voltage, Current
■ High accuracy with excellent stability
■ Reverse power protection and Built-in TVS/ESD protection
Specifications | |||
Output Interface | Analog Voltage 0-2V
(Output resistance ~0ohm) |
Analog Current 4-20mA
(Load Resistor<500ohm) |
RS485
Modbus-RTU |
Power Supply | 3.9-30V/DC | 12-30V/DC | 3.9-30V/DC |
Power Consumption | 6mA@24V DC | 30mA@24V DC
(with 20mA output signal) |
6mA@24V DC |
EC Measurement | Range: 0-5000us/cm, 10000us/cm, 20000us/cm
Resolution: 0-10000us/cm, 10us/cm; 100000-20000us/cm, 50us/cm Accuracy: 0-10000us/cm, ±3%; 10000-20000us/cm, ±5% EC temperature compensation: 0-50℃ |
||
Temperature Measurement | Range: -40~80℃, Resolution:0.1℃, Accuracy:±0.5℃ | ||
IP Ratings | Electrode:IP68
Transmitter:IP65 |
||
Operating Temperature | -40~85℃ | ||
Installation | Electrode:1/2″NPT screw threads
Transmitter:Mounting hole |
||
Cable Length | Power and Signal Cable:2 meters or Customize
Electrode Cable:5 meters |
||
Dimension | Electrode:1/2″NPT screw threads
Transmitter:128*70*42mm |
Parameters | Code | Comments |
Code 1:
Product Series |
ECTDS10 | ECTDS10 transmitter |
Code 2:
Measuring Parameters |
A | Conductivity, Salinity and TDS |
Code 3:
Electrode |
A
B C |
ABS electrode
Stainless steel electrode Customize |
Code 4:
EC Range |
A
B C D E |
0-20000us/cm
0-10000us/cm 0-5000us/cm 0-2000us/cm Customize |
Code 5:
Power Supply |
A
B |
3.9-30V DC (not applicable for analog current output)
12-30V DC |
Code 6:
Output Interface |
A
B C D E F G |
Analog Voltage 0-2V
Analog Current 4-20mA RS485,Modbus-RTU RS485,Modbus-RTU & Analog Voltage 0-2V RS485,Modbus-RTU & Analog Current 4-20mA SDI-12 Customize |
Code 7:
Cable Length |
002
XXX |
Electrode Cable:5 meters , Power and Signal Cable:2 meters
Electrode Cable:5 meters , Power and Signal Cable:xxx meters |
Ordering Code Example:
ECTDS10 transmitter with Conductivity measurement, ABS electrode, Conductivity Range 20000us/cm, Power Supply 3.9-30V DC, Output Interface RS485, Modbus-RTU, Power and Signal Cable Length 5 meters. Ordering Code is : ECTDS10 – A A A A C 005 |
- DigiGas-CD Carbon Dioxide CO2 Sensor, SDI1...
- DigiGas-OX Oxygen Concentration & Par...
- [Resource] MS10 Soil Moisture, Temperature...
- Resource-DigiTHP Air Temperature, Humidity...
- [Resource] Resource-FieldScan handheld sen...
- [Resource] SlabSense Substrate Moisture, E...
- Resource-CD10 CO2 Transmitter with RS485 M...
- Resource-DigiTH Air Temperature, Humidity ...