CD10-CO2 Carbon Dioxide Sensor Transmitter, RS485, Modbus
View:5543 Category:Gas Concentration Category:Measurements Category:Products
CD10 co2 transmitter integrated with dual channel non-dispersive infrared (NDIR) CO2 sensor. Dual channels consist of one CO2 channel that measures gas concentration and one reference channel that measures the sensor signal intensity. The sensor is applicable for science research, air conditioning, greenhouse, smart agriculture etc.
Resources | |
User Manual | UM-CD10 CO2 Carbon Dioxide Sensor Transmitter |
Software | SensorOneSet-EN |
CD10 co2 transmitter integrated with dual channel non-dispersive infrared (NDIR) CO2 sensor. Dual channels consist of one CO2 channel that measures gas concentration and one reference channel that measures the sensor signal intensity. The sensor is applicable for science research, air conditioning, greenhouse, smart agriculture etc.
■ Integrated with dual channel non-dispersive infrared (NDIR) CO2 sensor
■ 10-years long life sensing with temperature calibration
■ Output Interface with RS485, Voltage, Current
■ Immunity to background gas e.g. CH4、H2S、SO2、N2、O2 etc.
■ High accuracy with excellent stability
■ Reverse power protection and Built-in TVS/ESD protection
Specifications | |||
Output Interface | Analog Voltage 0-2V
(Output resistance ~0ohm) |
Analog Current 4-20mA
(Load Resistor<500ohm) |
RS485
Modbus-RTU |
Power Supply | 12-30V/DC | 12-30V/DC | 12-30V/DC |
Power Consumption | 60mA@24V DC | 80mA@24V DC
(with 20mA output signal) |
60mA@24V DC |
CO2 Measurement | Range 0-1000ppm, Accuracy ±(50ppm+3% Reading value) , Resolution 1ppm
Range 0-2000ppm, Accuracy ±(50ppm+3% Reading value) , Resolution 1ppm Range 0-5000ppm, Accuracy ±(50ppm+3% Reading value) , Resolution 1ppm Range 0-10000ppm, Accuracy ±(10% Reading value), Resolution 1ppm Range 0-30000ppm, Accuracy ±(10% Reading value), Resolution 1ppm Range 0-50000ppm, Accuracy ±(10% Reading value), Resolution 1ppm |
||
Temperature Measurement | Range: -40~80℃, Resolution:0.1℃, Accuracy:±0.5℃ | ||
Sensing method | Dual channel non-dispersive infrared (NDIR) CO2 sensor | ||
Warmup time | Max. 180 seconds | ||
IP Ratings | IP54 | ||
Operating Temperature | Temperature:-20-60 ℃
Humidity:0-95% RH (No condensation) |
||
Installation | Wall mounting | ||
Cable Length | 2 meters, or Customize | ||
Dimension | 130*70*42mm |
Parameters | Code | Comments |
Code 1:
Product Series |
CD10 | CD10 CO2 carbon dioxide sensor transmitter |
Code 2:
Measuring Parameters |
A
|
CO2 |
Code 3:
CO2 Range |
A
B C D E F |
0-1000ppm
0-2000ppm 0-5000ppm 0-10000ppm 0-30000ppm 0-50000ppm |
Code 4:Display | A
B |
With led display
No led display |
Code 5:
Power Supply |
A | 12-30V DC |
Code 6:
Output Interface |
A
B C D E F |
Analog Voltage 0-2V
Analog Current 4-20mA RS485,Modbus-RTU RS485,Modbus-RTU & Analog Voltage 0-2V RS485,Modbus-RTU & Analog Current 4-20mA Customize |
Code 7:
Cable Length |
002
XXX |
2 meters
Customize, XXX is required cable length(Unit: meter) |
Ordering Code Example:
CD10 CO2 carbon dioxide sensor transmitter, ?Range 0-5000ppm, With led display, Power Supply 12-30V DC,Output Interface RS485 Modbus-RTU, Cable Length 5 meters. Ordering Code is : CD10 – A C A A C 005 |
- [Resource] PH10 Non-Isolated PH Transmitte...
- ORP10-Oxidation Reduction Potential (ORP) ...
- [Resource] PYR20 Solar Radiation/Pyranomet...
- [Resource] DigiGas-CD Carbon Dioxide CO2 S...
- MEC10-Soil Moisture, EC and Temperature Se...
- Resource-DigiTH Air Temperature, Humidity ...
- [Resource] DigiGas-OX Oxygen Concentration...